Improving life during and after sedation
Products
Sedaconda acd
Sedaconda ACD* is a medical device for administering inhaled sedation to intubated and mechanically ventilated patients. Its unique and innovative design enables simple, effective, and predictable delivery of inhaled sedation.
*formerly known as AnaConDa
24h
Single-use product
90%
Reflection. Depending on the volume of the minute
99,867%
Bacterial filtration
99,76%
Filtration virale
50g
Device weight
HOW IT WORKS
The Sedaconda ACD is inserted in the breathing circuit between the endotracheal tube (ET tube) and the Y-piece and contains an evaporator which enables vaporisation of inhaled sedation.
Thanks to an effective carbon filter in the Sedaconda ACD, approximately 90% of the exhaled sedation is adsorbed during expiration and reflected back to the patient during inspiration, reducing the drug consumption. The Sedaconda ACD is also a very efficient Heat and Moisture Exchanger (HME) and contains a bacterial/viral filter.
INSPIRATION AND EXPIRATION
At the start of inspiration, air is transported from the ventilator and passes through the Sedaconda ACD. Liquid sedation agent from the syringe pump, delivered via the sedation agent line, is evaporated and transported with the airflow to the patient.
During expiration, approximately 90% of the sedation agent is absorbed by the reflector in the Sedaconda ACD.
At the next inspiration, the sedation agent is released from the reflector in the Sedaconda ACD together with new evaporated sedation agent and transported with the airflow to the patient.
Sedaconda ACD-L
Sedaconda ACD-L is a disposable medical device which enables the administration of volatile anaesth…
Sedaconda ACD-S
Sedaconda ACD-S is a medical device which enables the administration of volatile anaesth…
Sedaconda syringe
The Sedaconda Syringe is a 50/60ml syringe with a unique connection to fit the connector on the agent line of…
Sedaconda ACD Starter Kit
The Sedaconda ACD starter kit contains one Sedaconda ACD-S, and all the ancillary accessories required to….
Sedaconda (isoflurane)
Sedaconda (isoflurane) is indicated for the sedation of adult patients receiving mechanical ventilation in intensive care.
Sedaconda (Isoflurane)
Sedaconda is indicated for sedation of mechanically ventilated adult patients during intensive…
Sedaconda Filling Adapter
The Sedaconda Filling Adapter is a Class I, single-use medical device. It is designed to fit a standard…
Single-Use Standard Iso/Sevo Adapter
The single-use filling adapter is designed to fit standard threaded isoflurane and sevoflurane…
Scavenging
FlurAbsorb is an activated carbon filter, developed by Sedana Medical to capture residual anesthetic gases from ventilator exhaust.
Scavenging Tube
The Scavenging Tube is a one piece pre-connected tube, that is designed to channel anaesthetic waste gas from…
Mindray exhaust connector
The Mindray exhaust connector enables to connect the exhaust of the ventilator to an active or…
Gas monitoring equipment
The AMG-06 gas monitor is intended for continuous, non-invasive monitoring of CO2 and anesthetic concentrations in inspired and expired gases.
AMG-06 Gas Monitor
AMG-06 Gas Monitor is intended for continuous non-invasive sidestream monitoring of CO2 and…
Accessories
Dryline™ II Water Trap
The DRYLINE™ II Water Traps are intended for protection of side stream gas analyzers integrated in…
Gas Sampling Line H
The Gas Sampling Line H is intended for continuous monitoring of expired and…
Gas Sampling Line for BT-740
The Gas Sampling Line is for use with Sedaconda® ACD, please refer to the…